The new
CT motion SPICY

CT motion™ SPICY

chili

SPICY Features

pressure-performance_150px

Enhanced pressure and flow performance
For examinations with high flow rates and high contrast media viscosities.

remaining-volume_150px

Remaining volume indication
Easy-to-understand traffic light indication and clear display of available media volumes plus accurate ml indication.

1L-ge_150px

1L GE contrast media Pluspak compatibility plus heat maintaining

  • Ideal media supply for high patient throughput. 4L in total (2x 1L contrast media + 2L NaCl)
  • Optimal contrast media viscosity and patient comfort thanks to integrated heat maintaining
extended-performance-date_150px

Automatic media label recognition

  • Automatic media label recognition via barcode reader
  • Automatic data transfer to vendor-independent PACS and DMS
  • Less manual data entry necessary
cd-adapt_150px

CDadaptTM
Automatic contrast density reduction (e.g. for cardiac examinations) and simultaneously reduced costs for contrast media due to lower contrast media consumption.

Multi contrast media use

Icon_Extended_CM-Select_Tandem

Tandem for changing over contrast media

  • With the same active ingredients at the touch of a button
  • No changeover of the 24 h pump tubing required thanks to the automatic rinsing program
Icon_CMLoop_Seamless

Extended tandem**

  • Use of contrast media with different active ingredients
  • No changeover of the 24 h pump tubing required thanks to the rinsing program

**Extended Tandem requires additional application training.

Icon_Seamless

Seamless

  • Double contrast media supply thanks to automatic switchover with identical contrast media
  • Low contrast media wastage and increased patient throughput.
  • Patient changeover in just a few seconds*

*Compared to our products with only one contrast media connection point

Digital workflow - documentation has never been easier

SYNCopenTM

  • Interface between CT motion and CT scanner
  • Simplified and safe start of the examination via Single Button Start
  • Automatic transfer of the injection protocol once scan protocol has been selected
  • Patient safety: clear assignment of integrated scan and injection protocols
  • Quality assurance through the automatic sending of injection parameters to RIS/PACS or dose management systems

RIS/PACS Interface

  • Comprehensive documentation of the contrast media injection
  • Quick and standardized documentation using DICOM standard
  • Reduced error sources during data collection thanks to the standardized data transfer
  • Automatic documentation of the contrast media injection in PACS and/or dose management systems in combination with the patient data from the RIS
  • Availability of an injection history for the last 500 injections (on the touch terminal)
Innovative technology made in Germany

Two-piece tubing system

  • Optimized pump tubing XD 8151 for 24 h use for any number of injections
  • Fewer insertion steps simplify set-up procedure
  • Further improvement of the particle filter performance increases patient safety
  • Patient tubing with two check valves
tubing system

Injector display

Simple, safe and fast operation

 

Touch terminal

  • High-resolution color display
  • Wireless connection to injector
  • Capacitive touchscreen

 

Cordless operation

  • 24 h battery output
  • Lithium-ion battery

 

 

The CT motion is available as a wireless pedestal version for flexible positioning or as a ceiling version for small examination rooms.

Your advantages – user-friendly, simple, efficient
Simple to use

Simple to use

  • Set-up just once daily
  • Rapid patient changeover
  • Intuitive user interface
  • Optimal contrast media management with two connection points
Hygiene and patient safety

Hygiene & patient safety

  • 24 h use of the pump tubing1
  • Direct injection from the original media containers
  • Closed system
  • Reliable protection against retrograde contamination2
  • Injector and patient-side air detectors protect against air injection
Cost-effective and efficient

Cost-effective and efficient

  • Low costs for disposables due to 24 h approval of the pump tubing
  • Optimal contrast media management using large containers
  • High patient throughput thanks to efficient workflows

1 Source: GLP-compliant study: “Microbiological Contamination Control Study of CT motion System”, Report 12046497, dated: February 28, 2018, author: UL International GmbH (Grenzenstr. 13, 88416 Ochsenhausen, Germany); study is unpublished, but available on request with nondisclosure agreement.
2 Source: GLP-compliant study: “Virological evaluation of Retrograde Contamination Potential at the Pump Tubing Set (XD 8003) and the Patient Tubing Set (XD 2035) of the CT motion (XD 8000)”, Report 10874251 2.1, dated: November 12, 2015, author: UL International GmbH (Grenzenstr. 13, 88416 Ochsenhausen, Germany); study is unpublished, but available on request with nondisclosure agreement.

chili

These are our new SPICY features